![]() Problems with the gas and electrical system can cause a Rinnai error code 11, so they should be inspected for problems. Rinnai error code 11 is indicative of a problem with the ignition of the unit. Do not forget to check the dip switches and ensure they have been set correctly.Īlways use Rinnai approved venting materials as some materials can cause error code 10 due to incompatibility. They should also be of correct length and diameter. To fix the Rinnai error code 10, you need to ensure that the exhaust, vent pipes, condensation collar, and fans are installed and connected correctly and not blocked in some way. Rinnai error code 10 means that the air supply or the exhaust has been blocked. Error Code 10: Air Supply or Exhaust Blockage Lack of water pressure or a leak such as a broken or cracked water pipe connections can cause an error code 07. You need to confirm that the water supply is on, the water filter is not blocked or clogged, and it maintains a constant pressure of 30 psi. Rinnai error code 07 indicates that the flow rate has fallen below 2.1 GPM. Error Code 07: Circulation flow rate has dropped below 2.1 GPM If the error code persists, you may need to replace the bypass servo. Measuring the resistance of the bypass flow control can help in determining the problem. This code is not observed on all Rinnai water heaters. If your Rinnai displays an error code 05, you need to restart the water heater and open the hot water faucet. Rinnai error code 05 can be seen on Rinnai water heaters with installed bypass valves when there is an issue with the bypass servo. If you live in an area that experiences routine blackouts or power failures, you may need to look into a battery backup power supply for your tankless water heater. Rinnai error code 03 can be fixed by turning off all hot water taps and the ON/OFF button twice.īy restarting the unit, it should start working correctly. This commonly occurs when filling a bathtub, causing the water heater to stop producing hot water. Rinnai error code 03 indicates that there has been a power interruption or outage while the Rinnai water heater happens when in use. Error Code 03: Power interruption during Bath fill If you live in an area with routine freezing winter temperatures, we’ve put together the article Maintaining Tankless Water Heaters in Freezing Temperatures. The Rinnai error code 02 cannot be fixed by the user, and the only solution is to make a service call and have a certified technician inspect your Rinnai. Rinnai error code 02 indicates that the burner will not operate while the freeze protection mode is active. Error Code 02: No burner operation during freeze protection mode However, eventually, the water heater will stop working to prevent damage. ![]() Pushing the temperature controller’s ON/OFF button five times will allow you to run the water heater even if you haven’t cleaned the heat exchanger. Make sure to treat hard water to prevent scale build-ups in the future. You can find detailed information on cleaning and flushing the heat exchanger in your owner’s manual. It can be observed alternating between the current temperature setting and the LC error code, accompanied by a beeping sound. Rinnai error code 00 will usually be replaced by LC code, followed by a number between 0 to 9 in the maintenance code history. If this does not work, you may need to replace the heat exchanger. To fix this error code, you need to flush the heat exchanger. ![]() Rinnai error code 00 (or LC0, LC1, LC2, LC3, LC4, LC5, LC6, LC7, LC8, and LC9) indicates there has been scale build-up in the heat exchanger. Other Troubleshooting Tankless Water Heater Error Code Guides Error Code 00 (or LC0 through LC9): Scale Build-up in Heat Exchanger ![]()
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |